4 INPUT TERMINALS for more options, including 30ch for the first time!
Expandable from 20ch to max. 200ch, enabling measurement of various data
Compatible with Remote Control Service G-REMOTE.
Wireless Measurement from your PC with the Optional Wireless LAN unit.
6 NEW FEATURES:
Faster Sampling Interval
Memory Loop Functions
CH Copy function
Alarm history
Inter-CH Operation
Modbus Communication
additional FEATURES
7” Color LCD Display
8GB internal memory, SDHC to 32GB
20mV to 100 Vdc & 1-5 Vdc full scale ranges
Thermocouples: K, J, E, T, R, S, B, N, C, RTD
4 Pulse or Logic inputs, 4 Alarm Outputs
10ms to 1H sample intervals & ext. sample
Independent start / stop triggers & ext. trigger
Record to GBD or CSV file format
USB 2.0, Ethernet & optional Wi-Fi capability
GL28-APS / GL-Connection SW GUI /
G-Remote capableIndependent input type, alarm, trigger and
EU scaling per channel
All ChannelS Isolated / Universal Input / Standalone Multi-Channel
Voltage, temperature, and humidity can be selected for each input channel.
Use EU scaling for other measurement parameters.
Measure voltage
Supports wide operating range (from 20 mV to 100 V)
Measure temperature
Thermocouple : K, J, E, T, R, S, B, N, C (WRe5-26)
Measure current (4 -20 mA)
Shunt resistor (250Ω) is available as an option.
Equipped with a dedicated 1-5V range for the measurement range
Shunt resistance 250Ω (B-551)
Measure humidity
A humidity sensor is available as an option.
Power for the sensor is also supplied from the main unit.
Equipped with a dedicated humidity range
Humidity sensor (B-530)
Digital I/O port available
Digital I / O can be used by connecting an optional I / O cable.
Input/Output cable (B-513)
Logic/Pulse inputs (4 channels)
Logic: No-voltage contact (A contact, B contact, NO, NC) ,Open collector, Voltage input (H.L decision)
Pulse: 3 types of selections
(Rotation / Quantity count / Instantaneous) per channel
<Alarm output: 4ch>
Alarm conditions can be set for each input channel.
Signal output from outputs 1 to 4 is possible in the event of an alarm.
New service “G-REMOTE” *
Remote control and data capture can be easily performed using a web browser from anywhere with an Internet connection.
The recorded data can be backed up to a dedicated cloud server.
*Additional charge for use.
Optional Wireless LAN unit (B-568)
Optional Wireless LAN unit is available in limited region.
Wireless LAN option enables the wireless communication with the other devices.
Access Point enables direct connection to PCs and smart devices without a router.
Station enables connection to a wireless LAN router. Depending on the environment, data can be checked and e-mails can be received with remote PCs and smart devices via the Internet.
Built-in 8GB Flash Memory with SD Card Support
Ring capture function
The most recent data is saved when the memory is configured in ring memory mode. (Number of capturing data is 1000 to 2000000 points)
MEMORY LOOP function
In addition to the existing relay capture function, the oldest file is automatically deleted before memory capacity runs out.
Hot-swapping SD memory card
SD card can be replaced during data capturing when the sampling interval is 100ms or slower.
Back up recording data
The data file can be created periodically for purpose of backing up data while recording it, and the file is automatically transferred to another storage device on the unit or FTP server on the network.
Backup interval: 1, 2, 6, 12, 24 hour(s)
Backup file destination: SD memory card or FTP server
Data file format: GBD (binary) or CSV (text)
Figures are approximate. File size of captured data is 2GB in GBD or CSV file format on this chart.
Sampling interval is limited by the number of channels in use.(10ms:1ch, 50ms:5ch, 100ms:10ch)
The CSV format is available with firmware version 1.43 or rater.
Available sampling speed is the 100 ms or slower when using the CSV format.
When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
The storage device specified as the recording destination of the measurement data can not be set as the transfer destination of the backup file.
When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
relay capture function
Data is continuously saved to multiple files up to 2GB without losing any data until capturing is stopped when the memory is configured in the relay mode.
Data file verification
It is a function to check the integrity of the data file when replaying the data file. It compares check-sum generated from the data file and recorded check-sum. When two check-sums do not match, the data file may be corrupted or has been changed by someone. The check-sum code is recorded into the file when data file is created by the GL unit.
Check-sum code is added to normal data recording file and also file created for backup, ring or relay recording. Adding check-sum is available for data files created in GBD format.When the recorded data file is converted and saved using GL100_240_840-APS or GL-Connection software, the check-sum code will not match.
This function is available with firmware version 1.43 or rater.
USEFUL FUNCTIONS
Operability improvements
Accelerated Web server function
Simplified waveform setup
Hide unnecessary menus
Display HELP QR Code
Improved visibility (Improved display saturation and MENU tree / New font)
Alarm Output / History Functions
Improved Inter-CH Calculation
AUTO span
USB drive mode
3 Types of Power Sources
OVERVIEW | TERMINALS | G-REMOTE | SOFTWARE | SPECIFICATIONS | ACCESSORIES | DOWNLOAD